S-Series Server / Client Manual
Version 2.2.1 Rev 1/14/07
www.cascadiadvrt.com
Client Software
Remote Connection of a DVRT through a Router
When the DVRT is behind the router and has an internal IP (ex : 192.168.xxx.xxx), the
IP cannot be accessed from a remote site beyond the local area network. In order to
make the connection work in this environment, please follow the procedures below.
DVR
192.168.0.2
192.168.0.3 ………………
Router
ADSL/Cable Modem
Internet
LAN
Public IP (ex ; 66.177.175.243)
Port Forwarding
Forward the necessary ports to the DVRT from the router or firewall. Ports 80 & 8100
are essential.
 80 is for web server port
 8100 is for video streaming port
 8100 is for communication port with Dynamic IP Server
 8200 is for Live Audio
 8500 is for voice communication (Two-Way Voice)
Video streaming Port 8100
Web (http) Port 80
Register/Update to Dynamic
IP Server Port 8100
Voice Communication
Port 8500
Router
DVR
Live Audio Port 8200